12-Hour Digital Clock
intermediate · sequential · 200 XP
Sign in to write your solution, run it in the simulator and submit it for grading.
Sign in or create a free account →Problem
12-Hour Digital Clock
Chain BCD decade counters to build a complete **HH:MM:SS digital clock**. This is the capstone of the counter section — it requires parameterised counters, carry chaining, BCD, and rollover logic with non-standard boundaries.
**Interface**
| Port | Direction | Width | Description |
|-----------|-----------|-------|--------------------|
| `clk` | input | 1 | 1 Hz clock (1 tick/second) |
| `rst` | input | 1 | Synchronous reset |
| `s0[3:0]` | output | 4 | Seconds units (0–9) |
| `s1[3:0]` | output | 4 | Seconds tens (0–5) |
| `m0[3:0]` | output | 4 | Minutes units (0–9) |
| `m1[3:0]` | output | 4 | Minutes tens (0–5) |
| `h0[3:0]` | output | 4 | Hours units (combined with h1) |
| `h1[3:0]` | output | 4 | Hours tens (0 or 1) |
**Rollover rules:**
- `s0`: 0–9 → carry to s1
- `s1`: 0–5 → carry to m0 (seconds tens max = 5)
- `m0`: 0–9 → carry to m1
- `m1`: 0–5 → carry to hours
- **Hours: 01–12 → rolls to 01** (never 00, never 13)
On reset, clock starts at **12:00:00**.
**The 12→01 rollover** is the tricky part. Implement `h1` and `h0` separately. The rollover fires when `h1==1 && h0==2` (i.e. 12) — and rolls to h1=0, h0=1 (01:00:00).
Constraints
- 00:00:00 must never appear.
- 13:00:00 must never appear.
- Hours roll 12→01, not 12→00.
- Reset must initialise to 12:00:00.
- s1 and m1 max out at 5 (0–5 only).
Examples
Input: After reset
Output: h1=1, h0=2, m1=0, m0=0, s1=0, s0=0 (12:00:00)
Reset value
Input: At 12:59:59, next clk
Output: h1=0, h0=1 → 01:00:00
12→01 rollover
Input: At 01:00:00, next clk
Output: 01:00:01
Normal increment from 01
Common questions
- What does the 12-Hour Digital Clock problem ask you to build?
- 12-Hour Digital Clock Chain BCD decade counters to build a complete **HH:MM:SS digital clock**. This is the capstone of the counter section — it requires parameterised counters, carry chaining, BCD, and rollover logic with non-standard boundaries.
- What constraints does 12-Hour Digital Clock have?
- 00:00:00 must never appear.; 13:00:00 must never appear.; Hours roll 12→01, not 12→00.; Reset must initialise to 12:00:00.; s1 and m1 max out at 5 (0–5 only).
- What is an example input and output for 12-Hour Digital Clock?
- Input After reset gives output h1=1, h0=2, m1=0, m0=0, s1=0, s0=0 (12:00:00). Reset value
- Which Verilog concepts does 12-Hour Digital Clock practise?
- sequential, counter, BCD, capstone, clock.