BitFlow

RISC-V Step 5: First Datapath

advanced · riscv · 400 XP

Sign in to write your solution, run it in the simulator and submit it for grading.

Sign in or create a free account →

Problem

RISC-V Step 5: First Datapath Time to connect the parts into a CPU, `rv_cpu`. In this step it runs the **computational instructions**: | Group | Instructions | Result written to `rd` | |-------|--------------|------------------------| | OP (0110011) | ADD SUB SLL SLT SLTU XOR SRL SRA OR AND | `alu(x[rs1], x[rs2])`, op = `{funct7[5], funct3}` | | OP-IMM (0010011) | ADDI SLTI SLTIU XORI ORI ANDI SLLI SRLI SRAI | `alu(x[rs1], imm)` | | LUI (0110111) | `lui rd, imm` | `imm` (the U-type immediate) | | AUIPC (0010111) | `auipc rd, imm` | `pc + imm` (pc of this instruction) | Every instruction here writes a register and goes to `pc + 4`; there are no branches yet, so tests are straight-line programs. **Interface** (the same for steps 5 and 6) | Port | Dir | Width | Meaning | |------|-----|-------|---------| | `clk`, `rst` | in | 1 | Clock; synchronous active-high reset (PC = 0) | | `imem_addr` | out | 32 | Address of the instruction to execute (the PC) | | `imem_data` | in | 32 | That instruction; instruction memory reads combinationally | | `dmem_addr`, `dmem_wdata`, `dmem_we` | out | 32, 32, 1 | Data memory: byte address, store data, store enable | | `dmem_rdata` | in | 32 | Data memory read data at `dmem_addr` (combinational) | | `wb_en`, `wb_rd`, `wb_data` | out | 1, 5, 32 | Register write-back: 1 when this instruction writes `x[wb_rd] = wb_data` | The memories live in the testbench. The write-back port is how the tests see your results: they watch every register write. Drive your register file's write port from `wb_en`, `wb_rd` and `wb_data` so the two always agree. **Single-cycle:** each rising edge of `clk` finishes one instruction: registers and memory are written and the PC moves on. **While `rst` is high:** `wb_en` and `dmem_we` must be 0 and the PC goes to 0. `dmem_addr`/`dmem_wdata` only matter while loading or storing, and `wb_rd`/`wb_data` only while `wb_en` is 1. **Watch out for OP-IMM:** `funct7` is not an opcode field there; for ADDI, `instr[31:25]` is part of the immediate. Only the shifts use `instr[30]`, to tell SRAI from SRLI. Use `{instr[30], funct3}` for OP but only for SRAI/SRLI in OP-IMM. Your starter already contains your ALU, register file and immediate generator from steps 1–3 (or stubs, if you haven't solved them yet).

Constraints

  • One instruction per clock cycle.
  • wb_en and dmem_we are 0 while rst is high.
  • x0 stays 0 (the register file handles it).
  • Only these modules are graded: rv_alu, rv_regfile, rv_immgen, rv_cpu.

Examples

Input: addi x1, x0, 100

Output: wb_en=1, wb_rd=1, wb_data=100

x1 = 100

Input: addi x3, x0, -1024

Output: x3 = 0xFFFFFC00

Not SUB: instr[30] is an immediate bit here

Input: lui x5, 0x12345

Output: x5 = 0x12345000

U-type immediate

Input: auipc x6, 1 at pc 0x40

Output: x6 = 0x1040

pc + (1 << 12)

Common questions

What does the RISC-V Step 5: First Datapath problem ask you to build?
RISC-V Step 5: First Datapath Time to connect the parts into a CPU, `rv_cpu`. In this step it runs the **computational instructions**: | Group | Instructions | Result written to `rd` | |-------|--------------|------------------------| | OP (0110011) | ADD SUB SLL SLT SLTU XOR SRL SRA OR AND | `alu(x…
What constraints does RISC-V Step 5: First Datapath have?
One instruction per clock cycle.; wb_en and dmem_we are 0 while rst is high.; x0 stays 0 (the register file handles it).; Only these modules are graded: rv_alu, rv_regfile, rv_immgen, rv_cpu.
What is an example input and output for RISC-V Step 5: First Datapath?
Input addi x1, x0, 100 gives output wb_en=1, wb_rd=1, wb_data=100. x1 = 100
Which Verilog concepts does RISC-V Step 5: First Datapath practise?
riscv, risc-v, cpu, datapath, single-cycle.